Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C21-1153
Permit Type: Commercial Building Permit - None BldgNew
Address: W 160 48TH AVE Anchorage
Location: 160 W 48th Ave
Work Description: EPLANS-117094 SQFT, TYPE VB, OCCUPANCY R-1-GJS
NO CCO ON THIS PERMIT UNTIL SHARED ACCESS WITH C15-1806 IS RESOLVED. JCA 6/19/23 Resolved with change order X22-1625. JCA 8/13/24

**REVOKED MAIN PERMIT AND ISSUED CORE AND SHELL ONLY PER JUDY 6/19/23 - SEE HER COMMENTS UNDER PD CIVIL REVIEW - BWP**
Change order X22-1625 has been approved and this permit (C21-1153) has full PD Civil approval.  - RDO (Per PDCivil Final Review)
CONTRACTOR TRANSFER FORM [FROM ACSC BUILDER TO MAD-AK] ON 6-8-2026 - RLH
Status: Issued
Project Name: EPLANS- CANDLEWOOD SUITES/HOLIDAY INN EXPRESS
Review Type: Structural
Result: FandF
Result Date: 8/31/2021 10:07:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:


STRUCTURAL REVIEW COMMENTS

Project Name: C21-1153
Project Description: EPLANS- CANDLEWOOD SUITES/HOLIDAY INN EXPRESS

Review Comments List Date: 8/17/2021


Ref. # 97, 4/27/21 5:16 PM, Cycle 1


Markup: Struc 22, S2.0B.pdf


Please provide the size and details of footings and framing required for this canopy.


 


Ref. # 158, 8/17/21 3:43 PM, Cycle 3


Comment:


Please provide a drawing set with all plans marked "For Construction."


 


Ref. # 160, 8/17/21 3:50 PM, Cycle 3


Markup: Struc 38, S3.0B.pdf


It is not clear how the roof framing members are supported at the corner overhang; please provide framing connections or hangers.


 


Ref. # 161, 8/17/21 3:55 PM, Cycle 3


Markup: Struc 37, S3.0A.pdf


Please clarify the force transfer around diaphragm openings mechanism per the requirements of ASCE 7.


 


Ref. # 162, 8/17/21 4:00 PM, Cycle 3


Markup: Struc 39, S3.5.pdf


Architectural sheet A539 shows a different detail; please clarify.


 


Ref. # 163, 8/17/21 4:03 PM, Cycle 3


Markup: Struc 40, S6.1.pdf


Please provide a connection for out-of-plane wall forces at the top of the walls.




Ref. # 164, 8/17/21 4:04 PM, Cycle 3


Markup: Struc 41, S8.1.pdf


Please provide a connection to brace the wall for out-of-plane forces.


 


Ref. # 165, 8/17/21 4:06 PM, Cycle 3


Markup: Struc 42, S9.1.pdf


Pleas provide a shear transfer connection from the roof diaphragm to the wall.



Review Comments List Date: 8/31/2021

Ref. # 170, 8/31/21 9:58 AM, Cycle 4, Unresolved


Comment: Please provide structural construction drawings for the pool and spa areas that are sealed by an engineer registered in the State of Alaska. Please reference the "SP" drawings.

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS