Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C21-1153
Permit Type: Commercial Building Permit - None BldgNew
Address: W 160 48TH AVE Anchorage
Location: 160 W 48th Ave
Work Description: EPLANS-117094 SQFT, TYPE VB, OCCUPANCY R-1-GJS
NO CCO ON THIS PERMIT UNTIL SHARED ACCESS WITH C15-1806 IS RESOLVED. JCA 6/19/23 Resolved with change order X22-1625. JCA 8/13/24

**REVOKED MAIN PERMIT AND ISSUED CORE AND SHELL ONLY PER JUDY 6/19/23 - SEE HER COMMENTS UNDER PD CIVIL REVIEW - BWP**
Change order X22-1625 has been approved and this permit (C21-1153) has full PD Civil approval.  - RDO (Per PDCivil Final Review)
CONTRACTOR TRANSFER FORM [FROM ACSC BUILDER TO MAD-AK] ON 6-8-2026 - RLH
Status: Issued
Project Name: EPLANS- CANDLEWOOD SUITES/HOLIDAY INN EXPRESS
Review Type: Traffic Engineering
Result: Correction
Result Date: 3/16/2021 11:30:38 AM

Comments:

 Code SectionReview CommentStatus
121.07.040 FProvide required snow storage area calculations.


221.07.040 FShow required snow storage location on site plan or enter into snow management agreement with Municipality


321.07.060 E.4Provide required on site pedestrian walkways.


421.07.080No landscape drawings provided with this submittal.


521.07.080Show site distance triangles for driveway access to the right of way.


621.07.090 BProvide Zoning approved parking calculations for all use on proposed development site plan.


721.07.090 CProvide typical dimensions for proposed parking spaces to include length, width, angle and travel aisles.
Compact spaces are not allowed per Title 21.  Typical Spaces is 9ft x 20 ft.  Revise space size or eliminate spaces.

821.07.090 GProvide required loading berth calculations for proposed site development.


921.07.090 G.5Show location of required loading berths on site plan.


1021.07.090 H.5Provide electrical site plan showing location of parking lot lighting with required lighting calculations and glare statement.


1121.07.090 K
Provide minimum number of required bicycle parking spaces.
Sjow location of 4 required bicycle parking spaces on civil site plans

12-
Height of building will require 26 foot wide drive aisle around building to support aerial fire apparatus per IFC.  Contact AHJ on required widths for this site.

13-
Show location of proposed trach dumpster for servicing by solid waste services vehicle.

14Title 9Provide Haul Route Information to and from proposed import and export locations. Identify Import and export locations, construction hours of operation, and point of contact.


15MUCTDProvide note that pavement marking shall be 4" white unless otherwise noted.


16IncompleteTraffic comments are incomplete pending submission of additional information.  Additional Comments may be generated.


17-
Provide Standard Signpost detail to be used with proposed site plans on site.

18-
Provide standard wheel stop details

19-
Provide copy of shared access agreement with parcel to the south for driveway connection to "A" street.




Advisory Information: