Inspection #: 877097
Inspection Type: Final Electrical
Inspector: M.Green
Result: Correction
Comment: Progress electrical final inspection for Holliday 4th floor guest rooms 433-439 and 3rd floor guest rooms 301-310. Progress electrical final approved except as below.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
10/14/2025TransferCorrect Below* ADA room 436. Also, likely in other ADA rooms."Fabtex" powered curtains: 1. Do not appear to have a listing mark. 2. Directions show cord leads from motors installed in walls. Cords installed in walls are a clear violation of several subsections of 400.12 Uses Not Permitted. This serves as further evidence that the product is not listed.