| Date | Status | Code | Description | Ref | Location | Comments |
| 7/1/2021 | Transfer | Correct Below | * | | Upper mechanical area | Industrial control panel for Ansil calls for 15 amp max OCP for control board. Label circuits and Panels that feed control panel. |
| 6/25/2021 | Transfer | Correct Below | * | | Taylor brand ice cream maker and beverage cooler- units 831 and 856 | Ratings on equipment shown as 20 amp and 15 amp max supply over current protection. Circuits 8, 10 need to be protected by a 15 amp GFCI breaker. |
| 6/25/2021 | Transfer | Correct Below | * | | Hot dog cooker final connections incomplete. | Hot dog cooker receptacle will need to be GFCI protected circuits 50, 52, 54 |
| 6/25/2021 | Corrected | Correct Below | * | | High 120 volt receptacle. | Ready access for GFCI protection required. |
| 6/17/2021 | Transfer | Correct Below | * | | Kitchen Area | All receptacles that fit the category described in 2017 NEC 210.8 B shall be GFCI protected. Includes ceiling receptacles, water booster pump, water reverse osmosis system, circuits 44, 45. |