| Date | Status | Code | Description | Ref | Location | Comments |
| 6/25/2021 | Transfer | Correct Below | * | | Taylor brand ice cream maker and beverage cooler- units 831 and 856 | Ratings on equipment shown as 20 amp and 15 amp max supply over current protection. Ice cream maker has 30 amp rated plugs. Properly rated plug, receptacles, and overcurrent protection required to supply units. |
| 6/25/2021 | Transfer | Correct Below | * | | Hot dog cooker final connections incomplete. | |
| 6/25/2021 | Transfer | Correct Below | * | | High 120 volt receptacle. | Ready access for GFCI protection required. |
| 6/17/2021 | Corrected | Correct Below | * | | Kitchen Area | Ansil remains to be wired, and Hood install is incomplete. |
| 6/17/2021 | Corrected | Correct Below | * | | Kitchen | Added receptacle on outside wall of the cooler is incomplete. |
| 6/17/2021 | Transfer | Correct Below | * | | Kitchen Area | All receptacles that fit the category described in 2017 NEC 210.8 B shall be GFCI protected. Includes ceiling receptacles, water booster pump, water reverse osmosis system, circuits 55 57, and circuits 50 52 54 receptacles. |