Work Description: Work Descr: install an exterior walk-in freezer on a concrete pad. freeser dimensions are 24'x8'x8', slab dimensions underneath are 25'x9' // 192 sq ft freezer, $1,500 concrete slab, Remarks: mgm
Status: Closed
Project Name: FISH & WILDLIFE WAREHOUSE
Review Type: Structural
Result: Approved
Result Date: 9/8/2005 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

C(1): The seismic evaluation does not include 25% of storage loads and sliding of the unit under the total base shear shall be used for design of anchorage. The spectral acceleration used is conservative, however the net effect will be a greater lateral force. Lateral forces shall be resisted by positive connections to the footing without friction effects between the structure and the footing.