Permit Number: E05 5931
Permit Type: Commercial Trade Permit - Addition Electrical
Address: 7010 SAND LAKE RD Anchorage
Location:
Work Description: Work Descr: install an exterior walk-in freezer on a concrete pad. freeser dimensions are 24'x8'x8', slab dimensions underneath are 25'x9' // 192 sq ft freezer, $1,500 concrete slab, Remarks: mgm
Status: Closed
Project Name: FISH & WILDLIFE WAREHOUSE
Review Type: Structural
Result: Approved
Result Date: 9/8/2005 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

C(1): Informational Comment, No Action Neccessary The structure will be exempted from the minimum footing depth required for structures as specified by section 1805.2.1 as amended. Confirmation of non frost susceptible soils is recommended to the minimum cold foundation depth of 60" and ASCE 32-01 "Design and Construction of Frost-Protected Shallow Foundations" is referenced for recommended detailing.