Permit Number: E05 5931
Permit Type: Commercial Trade Permit - Addition Electrical
Address: 7010 SAND LAKE RD Anchorage
Location:
Work Description: Work Descr: install an exterior walk-in freezer on a concrete pad. freeser dimensions are 24'x8'x8', slab dimensions underneath are 25'x9' // 192 sq ft freezer, $1,500 concrete slab, Remarks: mgm
Status: Closed
Project Name: FISH & WILDLIFE WAREHOUSE
Review Type: Structural
Result: Approved
Result Date: 9/8/2005 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

C(1): The prefabricated refrigeration unit is evaluated as a non building structure under the 2000 IBC The structural evaluations provided are adequate for the structure. The ICC evaluation of the structure provided does not show reference of the structure and attachment for seismic loads and does not address the foundation of the unit. The following comments address elements of the structural evaluation and plan drawings which must be addressed prior to issuing a permit for this structure.