Permit Number: 04 5214
Permit Type: Commercial Building Permit - None BldgNew
Address: 9138 ARLON ST Anchorage
Location:
Work Description: Work Descr: 7319 sqft -occup M/ 8545 sqft- occup B, Remarks: gjs
Status: Closed
Project Name: LIBERTY VILLAGE
Review Type: Architectural
Result: Approved
Result Date: 1/25/2005 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): PANEL CUT SHEET Please provide a cut sheet for the insulated panel to show that the foam plastic has a flame spread index not more than 75 and a smoke-developed index not more than 450. Reference: IBC section 2603.3. C(2): VAPOR BARRIER CONTINUITY Please clarify how the continuity of the vapor barrier will be maintained at theroof/wall interface. Reference: IBC section 1403.3. 1/25/05 - Details have been provided.