Review Type: Mechanical
Result: Approved
Result Date: 3/22/2004 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): The following comments based on the 2000 International Building, Mechanical and Fuel Gas Codes must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the IBC, IMC, IFGC or any federal, state or local regulations. C(2): Is hood H-3 a type I hood? Please clarify. Since the exhaust duct penetrates a 2 hour shaft, a listed 2 hour rated grease duct or duct wrap is required to protect the shaft penetration and maintain the 2 hour continuity. RESOLVED 3-22-04. REVISED PLANS TO INDICATE 2 HOUR REQUIREMENT. TYPE II HOOD SERVES A TOASTER OVEN.