Permit Number:
03 5317
Permit Type:
Commercial Building Permit - None BldgAdd
Address:
3901 OLD SEWARD HWY Anchorage
Location:
Work Description:
Work Descr: 27441 sq ft First Floor, 8294 sq ft Second floor, Type II-B , Airconditioned, sprinklered, Remarks: cm
Status:
Closed
Project Name:
SADLERS STOCKROOM
Review Type:
Structural
Result:
Approved
Result Date:
12/16/2003 12:00:00 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. C(1): This review is for the customer pick-up portion of the Saddler's warehouse. The review is per the requirements of the 2000 International Building Code and all adopted references thereto as amended by MOA. The following comments must be addressed before approval of the change order can be given. THIS WORK HAS BEEN APPROVED. 12/16/03 CSK C(2): Reference IBC Sections 1605.2 and 1617.1, See calculations page 25: Please recheck wall overturning including redundancy factor, rho, in the overturning moment. RESOLVED 10/31/03 CSK - See new calcs.