Permit Number:
01 5006
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
700 G ST Anchorage
Location:
Work Description:
Work Descr: tenant improvements to 3ard floor and portion of 4th flr-, Remarks: cah
Status:
Closed
Project Name:
Review Type:
Architectural
Result:
Approved
Result Date:
1/24/2001 2:17:03 PM
Comments:
Code Section
Review Comment
Status
Advisory Information:
C(1): See detail 1 "Corridor Wall Type" on sheet A8.2. Corridor walls are only allowed to stop at a ceiling when the ceiling is part of an one-hour fire resistive assembly for the the entire story. Please clarify whether the ceiling is an one-hour assembly and update the plans if required. Reference: UBC 1004.3.4.3.1