Code Section
Review Comment
Status
1
_
Reviewer: Ross Noffsinger
ross.noffsinger@anchorageak.gov
343-8309
Status: 5/28/25 - Comments to be resolved.
1. Please clarify/verify the draft inducer is listed in accordance with UL 378 (per 2018 IFGC Section 503.3.3, Item No. 1) and verify the
venting system
meets both the fireplace and draft inducer installation instructions. Include the fireplace make/model.
2. Please verify compliance with IFGC Section 503.3.3, Item No. 5: Provisions shall be made to prevent flow of gas to the burners when the draft system is not performing so as to satisfy the operating requirements of the appliance for safe performance.