Permit Number:
C25-1432
Permit Type:
Commercial Building Permit - None Reroof
Address:
E 401 6TH AVE Anchorage
Location:
Work Description:
EPLANS - TEAR OFF AND REROOF. REMOVAL OF ROOFING SYSTEM TO DECK. INSTALL SINGLE LAYER OF 0.5" HD ISO WITH BONDING ADHESIVE PER MANUFACTUR SPECS. INSTALL 2 LAYERS OF 2.5" ISO FULLY ADHERED PER MANUFACTUR SPECS. SINGLE LAYER 60 MIL REINFORCED EPDM FULLY ADHERED PER MANUACTUR SPECS. 9034 SF, 1/12 -SBW
Status:
Issued
Project Name:
EPLANS - SHERATON REROOF
Review Type:
Structural
Result:
Correction
Result Date:
5/1/2025 1:41:31 PM
Comments:
Code Section
Review Comment
Status
Advisory Information:
1.
Please verify the coverboard is fully adhered.
2.
Please provide roof plan showing roof slope and drains where provided.