Permit Number: R25-1790
Permit Type: Residential Building Permit -None BldgAlter
Address: 9499 BRAYTON DR Anchorage
Location:
Work Description: MOBILE HOME CAUGHT FIRE DURING REROOF, FIRE DAMAGED RAFTES AND ROOF COVERING. ENGINEERED DRAWINGS INCLUDED FOR REPAIRS -SBW
Status: Issued
Project Name:
Review Type: Structural
Result: Correction
Result Date: 5/1/2025 2:56:46 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

COMMENTS HERE:

1. Submitted drawing printed on 8.5 x 11 sheet making text less than 3/32" please correct by enlarging the text to the minimum size requirement or provide a larger print.

2. Please clarify if the plywood bracing is to extend from top cord to bottom cord if required nailing is only at one location.

3. NDS Table C12.1.6.6 for recommended nail spacing for fasteners in a row has 15D for parallel and 10D for perpendicular, please clarify.