Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
C20-1361
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
3901 OLD SEWARD HWY Anchorage
Location:
Work Description:
MINOR EXTERIOR WORK AND PHASED INTERIOR ALTERATIONS ON BOTH FIRST FLOOR AND MEZZANINE, INCLUDING CHANGES TO THE LAYOUT OF EXISTING OFFICE SPACES AND RECONFIGURATION OF MEP AS NECESSARY-GJS
COVID 19 DISCOUNT APPLIED
Status:
Closed
Project Name:
DMV OFFICES
Review Type:
Architectural
Result:
Approved
Result Date:
6/1/2020 4:00:00 PM
Comments:
Code Section
Review Comment
Status
1
_
Resolved
Resolve Fire Plan Review comment on Manual Fire Alarm Boxes.
2
_
Resolved
Note that Unlimited Area per IBC Section 507.4 was identified in the code study. However, a combination of IBC Section 507.3 and IBC Section 507.6 could be cited since it is a one story building with a mezzanine and it does include an A-3 occupancy in a Construction Type IIB Building.
3
_
Resolved
Electrical Plans are not yet provided. Verification of Exit Signs and emergency lighting (including exterior emergency lighting at the new exit door 108) to be verified.
4
_
Resolved
The new exit door 108 correctly shows panic hardware due to the A-3 occupancy. Please verify that existing doors in the exit path from the A-3 occupancy have existing panic hardware.
Advisory Information:
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501