Permit Number:
C20-1361
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
3901 OLD SEWARD HWY Anchorage
Location:
Work Description:
MINOR EXTERIOR WORK AND PHASED INTERIOR ALTERATIONS ON BOTH FIRST FLOOR AND MEZZANINE, INCLUDING CHANGES TO THE LAYOUT OF EXISTING OFFICE SPACES AND RECONFIGURATION OF MEP AS NECESSARY-GJS
COVID 19 DISCOUNT APPLIED
Status:
Closed
Project Name:
DMV OFFICES
Review Type:
Architectural
Result:
Correction
Result Date:
5/13/2020 11:10:00 AM
Comments:
Code Section
Review Comment
Status
1
_
Resolve Fire Plan Review comment on Manual Fire Alarm Boxes.
2
_
Note that Unlimited Area per IBC Section 507.4 was identified in the code study. However, a combination of IBC Section 507.3 and IBC Section 507.6 could be cited since it is a one story building with a mezzanine and it does include an A-3 occupancy in a Construction Type IIB Building.
3
_
Electrical Plans are not yet provided. Verification of Exit Signs and emergency lighting (including exterior emergency lighting at the new exit door 108) to be verified.
4
_
The new exit door 108 correctly shows panic hardware due to the A-3 occupancy. Please verify that existing doors in the exit path from the A-3 occupancy have existing panic hardware.