Permit Number:
C20-1043
Permit Type:
Commercial Building Permit - None BldgNew
Address:
W 310 36TH AVE Anchorage
Location:
ALOFT HOTEL, 146 ROOMS
Work Description:
NEW CONSTRUCTION HOTEL (63,194 SQFT R-1 OCC. VA CONST.) (21,774 SQFT A-2 OCC. VA CONST). TOTAL SQUARE FOOTAGE 84,968, 146 ROOMS - MJD
Status:
Closed
Project Name:
ALOFT HOTEL
Review Type:
Traffic Engineering
Result:
Correction
Result Date:
2/20/2020 4:24:05 PM
Comments:
Code Section
Review Comment
Status
1
21.07.040 F
Show required snow storage location on site plan or enter into snow management agreement with Municipality
2
21.07.090 G
Provide required loading berth calculations for proposed site development.
3
21.07.090.G.7
Provide No Parking Loading Signs ( R7P-106) at proposed loading berth locations.
Provide No Parking Loading Zone signs for the 2 Type B loading berths
4
21.07.090 H.6
Proposed parking spaces dimensions overhangs into required pedestrian access routes. Widen sidewalk to minimum of 7 feet or provide wheel stops.
5
21.07.090 K
Provide minimum number of required bicycle parking spaces.
Site requires 5 parking spaces. Proposed location does not appear to meet the standard defined in 21.07.060 F.15 in relationship to primary entrance.
6
-
Provide detail for crosswalk striping shown on North east corner of site plan for pedestrian connection to ROW.
7
-
Provide Curb Returns per MASS for proposed driveways to existing curb and gutter. Reference standard mass deteail.
8
-
Provide detail for wheel stops for 18 foot parking spaces if sidewalks are not widen to 7 feet around perimeter of building
9
Incomplete
Traffic comments are incomplete pending submission of additional information. Additional Comments may be generated.
Advisory Information:
See review number 4