Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C19-2351
Permit Type: Commercial Building Permit - None BldgAlter
Address: 4000 CREDIT UNION DR Anchorage
Location:
Work Description: 7TH FLOOR EXECUTIVE BOARD ROOM RENOVATIONS TO INCLUDE P/M/E - BWP
Status: Closed
Project Name: ALASKA USAFCU - 7TH FLOOR
Review Type: Architectural
Result: Approved
Result Date: 11/26/2019 3:56:23 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:


Reviewed by: Bergstrom, Leigh W.

Phone: 343-8326

Fax: 249-7615

Email: BergstromLW@muni.org

Permit Manager: Bob Parker

Phone: 343-8391

Email: ParkerRW@muni.org

Project: ALASKA USA 7TH FLOOR

Review Number: 441333


1) “Please provide details for the attachment/fastening of the ceiling baffles. Please also provide the weight of the ceiling system including the metal baffles. Prescriptive suspended ceiling seismic bracing provisions only apply to ceilings of 4 psf or less per ASCE 7-10. If the ceiling weight exceeds this an engineered seismic restraint design is required.” Submit to structural on a deferred submittal basis.                      ARCHITECTURE IS APPROVED AS OF 11-26-2019.