Permit Type: Commercial Building Permit - None BldgAlter
Address: 3801 OLD SEWARD HWY Anchorage
Location:
Work Description:

IMPROVEMENTS TO THE BUILDING SHELL AND SITE ELEMENTS ONLY AT TENANT SUITE A-1 UNIVERSITY CENTER - RED

NOTE: THIS PERMIT WILL BE CLOSED OUT WITH A CERTIFICATE OF COMPLETION ONLY ONCE SHELL & SITE UPGRADES ARE COMPLETE. SEPERATE PERMIT TO BE SUBMITTED AT LATER DATE FOR INTERIOR TENANT IMPROVEMENT UPGRADES

Status: Closed
Project Name: UNIVERSITY CENTER -STE A-1 SHELL & SITE IMPROVE
Review Type: Traffic Engineering
Result: Correction
Result Date: 7/12/2019 2:23:25 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

Comments on 7/11/19 submittal;


1. Provide Haul Route information to and from import and export locations.  Identify proposed import and export locations


2. Provide additional information at west curb cut near cart corral.  Is this meant for pedestrian access from Main parking lot?  if so ensure there is a five foot wise cut for pedestrian accessibility.  Add No parking sign for the hatch space next to cart coral.


3.  It appears that a crosswalk is proposed in the 26 foot drive aisle.  Provide appropriate detail for cross walk showing 2 foot wide strips  with 2 foot on center spacing for the 8 foot wide walk.  Color to be striped shall be white.  Add a no parking sign for the hatch area near center curb cute  at face of sidewalk offset from main five foot path.


4. Adjust and ad notes to accessible parking details on Sheet C10.  Note 1 indicates 9 foot space but detail and site plan shows the standard 8 foot spacing.  Add note that pavement marking shall be 4 inch blue for spaces and aisle striping to include face of curb and or wheel stops.


Traffic comments incomplete pending submission of additional information  7-12-19~RR