Permit Number: C19-1616
Permit Type: Commercial Building Permit - None BldgAlter
Address: 4000 CREDIT UNION DR Anchorage
Location: 7TH FLOOR
Work Description:

7TH FLOOR TENANT IMRPVEMENT TO INCLUDE P/M/E - RED

OFFICE RECONFIGURATION W/ WALLS OVER 9 FEET IN HEIGHT

Status: Issued
Project Name: ALASKA USA - 7TH FLOOR HQ TI
Review Type: Structural
Result: Correction
Result Date: 6/20/2019 9:46:58 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

STRUCTURAL REVIEW COMMENTS

 

 

Reviewed by: David Misiuk, PE                        

Phone: 343-7585                                                                     

Email: david.misiuk@anchorageak.gov

 

Permit Manager: Richard Dienes-Oehm

Phone: 343-8034

Email: Dienes-OehmRE@muni.org

 

Permit #: C19-1616

Project: Alaska USA Headquarters 7th Floor Tenant Improvement

 

Date: June 20, 2019

____________________________________________________________________________________

 

STRUCTURAL REVIEW STATUS

06/20/2019 – Initial review complete; additional submittals are required.

 

 

This review is based on the requirements of the Anchorage Municipal Code (AMC), 2012 International Building Code (IBC) and all adopted references thereto as amended by MOA. The following comments must be addressed before a permit can be issued. The approval of plans and specifications does not permit the violation of the codes, or any federal, state or local regulations.

 

  1. Drawing sheet A-1 specifies 25 ga metal stud walls at 16” on-center and drawing A-2 calls for the use of 20 ga studs. Please verify that the walls will be 20 ga x 3-5/8” and indicate the wall height.

     

  2. Please provide details of structural conditions at top of wall for parallel and perpendicular existing structure indicating top of wall bracing.

 

  1. Please provide header and jamb requirements and connection details at wall openings. Submittal of details on 8-1/2 x 11 sheets would be adequate.

     

     

     

Please address each comment and include one copy of additional/revised calculations and two copies of additional/revised drawings. Please indicate the location of any additions or corrections in the response. All documents should be submitted to the permit manager as shown above.