Permit Number: X19-1382
Permit Type: Commercial Building Permit - ChangeOrdr BldgAlter
Address: 4901 SPENARD RD Anchorage
Location:
Work Description: SCOPE CHANGE - REMOVE FACADE IMPROVEMENTS FROM PROJECT AND CREATE SEPERATE PERMIT FOR FACADE SCOPE (OK PER G. STULLER 5/20/2019) - RED
Status: Closed
Project Name: Change Order of Bldg App C19-1470
Review Type: Fire
Result: Correction
Result Date: 5/29/2019 8:50:00 AM

Comments:

 Code SectionReview CommentStatus
1_
(1) This is a type V A building. The plans do not show one hour protection of the primary structural elements to the porte cochere or the canopy. (2) The canopies show combustible construction and they show they are greater than 4 foot wide. Are there plans to sprinkler the canopies. 