Permit Number:
C19-1055
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
2801 DEBARR RD Anchorage
Location:
Work Description:
REMODEL OF ARH SENIOR CLINIC TO INCLUDE MECHANICAL AND ELECTRICAL - SIL
Status:
Closed
Project Name:
ARH SENIOR CLINC
Review Type:
Architectural
Result:
Correction
Result Date:
1/25/2019 6:42:00 PM
Comments:
Code Section
Review Comment
Status
1
_
Drawing A020, Code Synopsis; Verify that this TI is being performed as an 2012 IEBC Level 2 Alteration.
2
_
Drawing A021, Vertical Assembly Types; Interior Partition Type E indicates a 2 hour assembly with existing wood framing. How is this possible in a non-combustible Building Type IIB? I could not find where Interior Partition Type E is called out on the plans; please clarify.
3
_
Drawing A701, Door and Frame Schedule; Door 208 does not have any data indicated on the Door and Frame Schedule. I assume that Door 208 has identical data as indicated for Doors 202, 203, 204, and 205. Please verify.
4
_
Drawing A701, Door and Frame Schedule; Doors 202, 203, 204, 205, 208, 215A, and 222 are indicated indicated as existing 32" on the Door and Frame Schedule. I am not sure how office and toilet doors opening into a corridor could have been code compliant when the building was built. Please clarify.
5
_
Drawing A402, Interior Elevations; Break Room - N is shown on detail 2; however, this detail does not verify that the reinstallation of the Break Room - N sink will be in compliance with the accessibility requirement for a maximum of 34" AFF to the Sink Flood Rim. This detail references Mechanical; however, the M sheets also do not indicate compliance with the accessibility requirement for a maximum of 34" AFF to the Sink Flood Rim..
Advisory Information: