Permit Number: C17-1961
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 401 6TH AVE Anchorage
Location:
Work Description: GUESTROOM AND LOBBY RENOVATION. FINISHES ON ALL FLOORS. ALL ROOMS REMODELED.  TO INCLUDE ELECTRICAL (ADDING OUTLET IN EACH ROOM).  AE
Status: Closed
Project Name: SHERATON ANCHORAGE HOTEL AND SPA REMODEL
Review Type: Architectural
Result: Approved
Result Date: 10/20/2017 1:07:00 PM

Comments:

 Code SectionReview CommentStatus
1_Resolved
The code study indicates that the project is a level 1 alteration to chapter 7 of the IEBC.  However, the plans Drawing I-114 indicates the removal of several connector doors between rooms on the 6th and 7th floors.  Thus, for at least for the  6th and 7th floors, the project is a level 2 alteration to chapter 8 of the IEBC to include  both chapter 7 and 8 of the IEBC.