Permit Number: C17-1852
Permit Type: Commercial Building Permit - None BldgAlter
Address: W 320 5TH AVE Anchorage
Location:
Work Description: COMMERCIAL T/I: DEMO EXISTING  WALLS & FINISHES; FRAME NEW WALLS , R&R ACOUSTAL CIELING TILES, NEW FLOORING/ PAINT, PLUMBING AND HVAC FOR NEW KITCHEN EQUIPMENT-SM
Status: Closed
Project Name: ALASKA CAKE STUDIO AND BOUTIQUE
Review Type: Fire
Result: Correction
Result Date: 8/28/2017 4:30:25 PM

Comments:

 Code SectionReview CommentStatus
1_
Refer to Sheet G0. The construction type for the 5th Avenue Mall is Type I. Based on previous projects, Type I-B is considered the most applicable. Please revise the code study accordingly.
Reference: IFC Section 105.4.2


2_
Refer to Sheet G0. Please clarify the rating of the fire extinguishers.
Reference: IFC Section 906.3


3_
Please provide information on the construction of the partition walls.
Reference: IFC Section 105.4.2


4_
Please provide information on the freezer panels to show compliance with foam plastic insulation requirements.
Reference: IFC Section 803.7


5_
Plans call for a Type I hood over the kettle and ovens. Please note a separate fire systems permit will be required for the suppression system.
Reference: IFC Section 904.11; AMC 23.45.K103.4