Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C16-2006
Permit Type: Commercial Building Permit - None BldgNew
Address: E 1715 64TH AVE Anchorage
Location:
Work Description:

Pre-Approved, pending approval of C16-2005. Mirrored plans of C16-2005. Work to include Architectural, Structural, Fire, Electrical, Plumbing, and Mechanical.S-1 : 18360sqft - AJC  



Status: Issued
Project Name: DOWLING WAREHOUSE RENTALS BLDG B
Review Type: Traffic Engineering
Result: Approved
Result Date: 3/8/2017 8:38:11 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

1. Provide haul route information to and from proposed import and export locations. Identify the proposed import and export locations. Comment Addressed 1-27-17


2. Provide recorded snow management agreement with municipality for alternative snow management solution. Contact Sonnet Calhoun in Planning for application.  Comment addressed 3-8-17


3. Sheet C4.0 - Provide additional sheet notes to the plan. A) All pavement markings shall be painted with 4" white striped unless otherwise noted. B) All accessible parking spaces shall be painted with 4" blue stripes. All curb /wheel stops to be painted blue for accessible space Comment Addressed 1-25-17


4. Sheet C4.0- Provide an R&P-101 "No Parking Anytime" for the van accessible aisles. Add sign information to sign stable. Indicate location of these signs on the plan. Comment Addressed 1-25-17


5. Sheet C4.0 -Provide Dimensions to include width and radius information for driveway connection to East 64th Avenue. Comment Addressed 1-25-17


6. .Sheet C4.0 - Class A loading berths shown. Please provide information that demonstrates turning and maneuverability for a semi-truck vehicle. Response
provided does not address the comment. Provide requested information demonstrating maneuverability of WB-50 or obtain variance or approval from zoning on reduction in type of loading berths required.
Reduction in loading berth type approved by Municipal Traffic Engineer.

Comment Addressed 1-3-17~RR


7. Sheet L1.0 - Show sight distance triangles for driveway at East 64th Avenue. Comment Addressed 1-3-17~RR

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS