Permit Number:
X16-1741
Permit Type:
Commercial Building Permit - ChangeOrdr BldgAlter
Address:
2801 DEBARR RD Anchorage
Location:
Work Description:
DOCUMENTING CEILING SYSTEM MEETS INTENT OF CODE FOR SMOKE PARTITION SHEATHING TERMINATING TO THE UNDERSIDE OF THE CEILING.
Status:
Closed
Project Name:
Change Order of Bldg App C16-1461
Review Type:
Architectural
Result:
Approved
Result Date:
8/30/2016 12:36:00 PM
Comments:
Code Section
Review Comment
Status
1
_
Resolved
This change order is approved. The Alternate Means and Methods Request is not required for its approval, since this proposed method of installing the lay-in ceiling tile as capable of limiting the transfer of smoke in accordance NFPA 101, Sections 18.3.6.2 and 19.3.6.2.4 meets the intent of 2012 IBC Section 710.4.