Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
C16-1126
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
W 5000 INTERNATIONAL AIRPORT RD Anchorage
Location:
Work Description:
Comm T/I to include plumb/mech/electric - New wine bar on upper mezzanine in art museum area - BWP
Status:
Closed
Project Name:
SLEEPING LADY WINE BAR & LOUNGE
Review Type:
Fire
Result:
Correction
Result Date:
3/10/2016 1:38:49 PM
Comments:
Code Section
Review Comment
Status
1
_
SHT. BC-1- Please revise occupancy calculations for Gallery Areas as calculations based on 1:300 or 1:30 is not applicable to the current 2009 Code standard currently approved in Municipality. Please revise calculations and code study accordingly including exit widths to accommodate at 15 net. IFC Table 1004.1.1
2
_
Sht. ID0.0 -Please advise are the exit stairs enclosed? The travel distance note appears insufficient as the travel distance measured along the exit access path should include travel on a stairway if it is not constructed to meet the definition of an exit. Please revise plans to show travel distance as measured to an exit. IFC 1016.1
Advisory Information:
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501