Permit Number: C16-1117
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description:

INTERIOR BUILDOUT TO BE A GAMESTOP STORE-GJS

CONTRACTOR ASSIGNED TO PERMIT.  PAID $600.00 FOR INSPECTIONS.  CONTRACTOR WILL PICK UP PERMIT AND DRAWINGS FALL 2017 - 6/6/2017 MJD

Status: Closed
Project Name: GAMESTOP
Review Type: Architectural
Result: Correction
Result Date: 2/23/2016 12:11:32 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

Architectural Comments

                                                                

                                                

Reviewed by: David Abuobaid                                                   Permit #: C16-1117

Phone: 343-8333                                                                        Date: 2/23/2016

Fax:     249-7775

Email:  AbuobaidDH@muni.org

Permit Manager: Bob Parker

Phone: 343-8319

E Email: ParkerRW@muni.org

Project: Game Stop (Fax: no fax provided)

________________________________________________________________________________

1.  The following comments based upon the 2009 International Building Code (IBC) must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the IBC or any federal, state or local regulations. 

 

2.  CODE REVIEW (CONSTRUCTION TYPE):

Sheet T1. The code review states the construction type is II-B. Please note that the construction type of the Dimond Center tower is 1-A. Please correct the construction type on the plan.

 

3.  FIRE RATED CONSTRUCITON:

Sheet A2 (“2” Partition Types - Fire Rated Partition Walls and Ceiling). Since the type of construction is

1-A and sheet A2 shows new suspended ceiling and metal studs attached to structure. Provide details on brace connection and how the individual structure member fire protection would be maintained.   

 

4. When the above comments have been addressed, please update the plans at the MOA Plans Review Office with three sets of revised architectural pages to include clouded changes, engineers stamp and signature. 