Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C15-1161
Permit Type: Commercial Building Permit - None BldgNew
Address: 1612 ANCHORAGE PORT RD Anchorage
Location:
Work Description:

3,150 sq ft comm bldg and bulk fuel tank / tb **Master file tank farm & controls bldg**

C15-1215 780 sq ft new truck loading/fuel station bldg; C15-1216 Bulk fuel tank & retaining wall

MOA & FIRE - 1/2 size; FIELD full size

Status: Expired
Project Name: POA BULK TERMINAL DELTA WESTERN
Review Type: Traffic Engineering
Result: Correction
Result Date: 9/17/2015 11:31:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

Comments for 9/14/15  submittal: Corrections; DB

 

1.) The intended haul route is provided by map.  The emergency contact person shall be Fritz Kaiser - 907.279.1405.  List the days and hours of haul route use and submit a traffic control plan, if required.  The shortest, most direct route, which minimizes travel on local and collector roadways shall be used. 

 

2.) A portion of the total number of parking spaces provided in each parking facility for this use shall be accessible parking.  The site shall provide a minimum of one van accessible parking stall.  Accessible parking serving the building shall be at least eight feet wide with a abutting van accessible access aisle eight feet in width.  Accessible car spaces and access aisles shall be level with surface slopes not exceeding 2% in all directions.  Please label dimensions for ADA parking and aisle.  Show spot elevations or slope percentage for ADA parking and access aisle.  Include details for R7P-101 - NO PARKING, R7-8A -VAN ACCESSIBLE and R7-8 RESERVED PARKING signs for accessible parking and aisle.

Item 2 has not been adequately addressed. ADA Parking dimensions are incorrect, minimum parking stall depth is 20'. Curb Stops or other means are required to prevent encroachment into the required 5' walkway area(7' from building) Show max 2% slope / cross slope for ADA parking, access aisle and accessible route. Provide the sign installation details as requested. Dimension all striping and drive aisles to meet required parking layout design per AMC 21.07.090. Show accessible route from the van accessible parking to the accessible entrance.~9/17/15 ~DB

 

3.) Approved for core and shell work to proceed at owner's risk.  Prior to issuance of any conditional or final certificate of occupancy, the applicant shall resolve all outstanding comments.  7/7/15 ~DF~

 

4.) Resolve parking requirement determination with Zoning. 9/17/15 ~DB

 

5) This review shall be considered incomplete pending receipt and approval of the requested revisions or additional comments. 9/17/15 ~DB~

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS