3,150 sq ft comm bldg and bulk fuel tank / tb **Master file tank farm & controls bldg**
C15-1215 780 sq ft new truck loading/fuel station bldg; C15-1216 Bulk fuel tank & retaining wall
MOA & FIRE - 1/2 size; FIELD full size
Comments for 6/23/15 submittal:
1.) The intended haul route is provided by map. The emergency contact person shall be Fritz Kaiser - 907.279.1405. List the days and hours of haul route use and submit a traffic control plan, if required. The shortest, most direct route, which minimizes travel on local and collector roadways shall be used.
2.) A portion of the total number of parking spaces provided in each parking facility for this use shall be accessible parking. The site shall provide a minimum of one van accessible parking stall. Accessible parking serving the building shall be at least eight feet wide with a abutting van accessible access aisle eight feet in width. Accessible car spaces and access aisles shall be level with surface slopes not exceeding 2% in all directions. Please label dimensions for ADA parking and aisle. Show spot elevations or slope percentage for ADA parking and access aisle. Include details for R7P-101 - NO PARKING, R7-8A -VAN ACCESSIBLE and R7-8 RESERVED PARKING signs for accessible parking and aisle.
3.) Approved for core and shell work to proceed at owner's risk. Prior to issuance of any conditional or final certificate of occupancy, the applicant shall resolve all outstanding comments. 7/7/15 ~DF~
4.) This review shall be considered incomplete pending receipt and approval of the requested revisions or additional comments. 7/7/15 ~DF~