Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: X15-1422
Permit Type: Commercial Building Permit - ChangeOrdr BldgAdd
Address: 2500 MINNESOTA DR Anchorage
Location:
Work Description: Additional support steel for Romig Business Unit / tb
Status: Closed
Project Name: Change Order of Bldg App C14-1705
Review Type: Structural
Result: Approved
Result Date: 6/10/2015 7:58:27 AM

Comments:

 Code SectionReview CommentStatus
1_Resolved

NEW OPENINGS IN CMU

ACI 530-08 section 1.17.3.2.3.1 requires vertical reinforcement of at least 0.2 square inches in cross sectional area within 16" of each side of an opening. Please verify that this reinforcement exists or provide details showing how this reinforcement will be provided if it does not exist.






Advisory Information:

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS