Permit Number: C15-1104
Permit Type: Commercial Building Permit - None BldgAlter
Address: W 320 5TH AVE Anchorage
Location:
Work Description:

Unit# D20A - Comm T/I to include plumb/mech/electric - BWP

 

**Contractor to pay for inspections and any additional charges**

Status: Closed
Project Name: Lululemon Athletica
Review Type: Architectural
Result: Approved
Result Date: 3/23/2015 9:45:00 AM

Comments:

 Code SectionReview CommentStatus
1_Resolved

STATUS:   3-02-15 Comments to be addressed.

The following comments based upon the 2009 International Building Code (IBC) must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the IBC or any federal, state or local regulations.



2_Resolved
G003 Building Code Summary         The existing building is 4 stories (not 1) and Type I-B construction (not V-N). Please adjust the code study.

3_Resolved
A120          Provide clarification to keynote #4 (HVAC) pointing to the oval soffit.

4_Resolved
Provide structural and seismic calculations plus fastening details for the soffit ceiling (A121) and the overhead coiling security grilles 01 & 01A (1/A714) to include engineers stamp and signature on a deferred submittal basis.

5_Resolved
3/A212         The 2'-10" dimension to the countertop is a maximum dimension to the flood rim of the sink per ICC/ANSI A117.1-606.3. Please clarify.

6_Resolved
A310         The maximum allowable dimension AFF for the horizontal grab bars at an ADA water closet is 36" to the top of the gripping surface per ICC/ANSI A117.1-609.4. 

7_Resolved
A310            The maximum allowable ADA mirror mounting height is 40 " AFF to the bottom of the reflecting surface per ICC/ANSI A117.1-603.3. Please clarify.

8_Resolved
A610           The back corridor is rated for 1-Hour requiring door #7 to be rated for 45 minutes per IBC Table 715.4. Provide clarification.