Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C15-1031
Permit Type: Commercial Building Permit - None BldgAlter
Address: W 320 5TH AVE Anchorage
Location:
Work Description:

TENANT IMPROVEMENT TO INCLUDE ARCH, PLBG,MECH,ELEC-GJS

REASSIGNED TO BOB PARKER-GJS

Status: Closed
Project Name: JOURNEY'S
Review Type: Fire
Result: Approved
Result Date: 2/6/2015 11:43:00 AM

Comments:

 Code SectionReview CommentStatus
1_Resolved
Page A6.1, detail 1 shows a plywood bulkhead.  This is a IB building, IBC 603 does not allow plywood in this application. 

FRT information provided and plans redlined for wood blocking. Approved.

2_Resolved
Page A5.2 Interior elevations show use of OSB as finish wall coverings.  Provide spec sheet/mfg sheet showing it meets Table 803.9 for flame and smoke.

FRT information provided and plans redlined for wood blocking. Approved.

3_Resolved
Page A5.2-wood blocking at side elevation of lavatory should be FRT wood, show on plans.

FRT information provided and plans redlined for wood blocking. Approved.




Advisory Information: