Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: X15-1058
Permit Type: Commercial Building Permit - ChangeOrdr BldgAlter
Address: W 5000 INTERNATIONAL AIRPORT RD Anchorage
Location:
Work Description: DEFERRED PHASE I BAG HANDLING SYSTEM SEISMIC STRUCTURAL CALCULATIONS AND FULL SIZE PLANS
Status: Closed
Project Name: Change Order of Bldg App C14-1543
Review Type: Structural
Result: Approved
Result Date: 1/26/2015 12:40:00 PM

Comments:

 Code SectionReview CommentStatus
1_Resolved

HIGH SEISMIC FACTOR

Reference page 11 of the calculations. It doesn’t appear as if the high seismic factor of ACI 318-08 section D.3.3.3 has been included in the design. This occurs elsewhere in the design; however it appears to only affect the design shown on page 11 of the calculations. Please clarify.






Advisory Information: