Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C15-1015
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description:

Comm T/I to include plumb/mech/electric - Contractor to pay for Inspections - Charge additional expedited fees if over 60 inspections to MBH Architects -  BWP

 

**DO NOT ISSUE UNTIL C14-1563 HAS A CO OR CCO**   

Status: Closed
Project Name: H & M RETAIL
Review Type: Architectural
Result: Correction
Result Date: 1/15/2015 6:15:58 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

Reviewed by: Crafts, Donald E.                                                  Permit #: C15-1015

Phone: 343-8451                                                                        Date: 01/15/15

Fax: 249-7652

Email: CraftsDE@muni.org

Permit Manager: Robert Parker

Phone: 343-8391

Email: ParkerR@muni.org

Project: H & M Retail (Buildout) - 800 E DIMOND BLVD

Review Number: 345607

 

1.  Status: Architectural Corrections required.  01/15/15

 

2.  The following comments based on the 2009 International Building Code (IBC) and 2009 International Existing Building Code (IEBC) must be resolved before a permit is issued.  The plans and specifications do not permit the violation of any section of the IBC or any federal, state, or local regulations.

 

3.  Drawing No. A-000.00, Code Analysis, Applicable Codes; Revise: National Electric Code (NEC) 2008 Edition to National Electric Code (NEC) 2011 Edition. 01/15/15

 

4.  Drawing No. A-000.00, Code Analysis, Construction Ratings; This is a “Construction Type I-A" Building.  As such, several of these Construction Ratings are incorrect per IBC Table 601.  Revise: Columns, Interior Bearing Walls, Beams, Girders, & Trusses indicated as non-rated To: Columns, Interior Bearing Walls, Beams, Girders, & Trusses indicated as 3 Hour Fire-Resistance Rated.  In Addition, Revise: Roof/Ceiling Construction indicated as non-rated To: Roof/Ceiling Construction indicated as 2 Hour Fire-Resistance Rated.  Note: "Trusts" should be corrected to indicate "Trusses" (this is an apparent typo).  It is clear that most, if not all, of the rated assemblies are within the landlords scope of work; however, it has to be clear on this set of plans what these required assembly ratings are, in case they get damaged during this Tenant Improvement.  01/15/15

 

5. Drawing No. A-000.00, Code Analysis, Occupant Load Calculations; In both the Upper Level and the Lower Level there is a significant area indicate as non-occupied areas.  Please indicate what these areas are used for.  01/15/15

 

6. Drawing No. A-011.00, Reference Notes, Note 12; Any core drilling thru a Fire-Resistance Rated Floor requires a Listed Rated Fire Stop Assemble.  Refer to IBC Section 713.4.1.1.2, for floor thru penetrations.  01/15/15

 

7. Drawing No. A-012.00, CC Multiple Accomodation Sanitary Facilities; The Accessible Toilet Room W.C.s require Grab Bars per 2003 ICC/ANSI A117.1 sections 604.5 and 609.  Please provide the 18 inch vertical grab bar located 39 to 41 inches from the back wall and 39 to 41 inches from the floor as shown on 2003 ICC/ANSI A117.1 Fig. 604.5.1.  01/15/15

 

8. Drawing No. A-012.00, CC Multiple Accomodation Sanitary Facilities; Verify that the Mirrors above the Lavatories in this handicap bath room meets accessibility requirements per "Accessible and Useable Buildings and Facilities" (ICC/ANSI A117.1) 2003.  The Mirrors above the Lavatories should be located with a maximum of 40 inches from the reflective surface above the floor per ICC/ANSI A117.1-2003 Sec. 603.3.  Please Clarify Diagram.  01/15/15

 

9. Drawing No. A-012.00, CC Multiple Accomodation Sanitary Facilities; Provide protection against contact with exposed pipes and surfaces per "Accessible and Useable Buildings and Facilities" (ICC/ANSI A117.1) 2003.  The protection should be insulated or otherwise configured per ICC/ANSI A117.1-2003 Section 606.6.  01/15/15

 

10.  Drawing No. A-601.00, Storefront Elevation; Verify that Security Grills comply with all of the requirements per IBC Section 1008.1.4.5.  01/15/15

 

11.  Drawing No. A-603.00, Storefront Elevation (and other drawings); Verify that safety glazing is provided in all required locations per IBC section 2406.3.  01/15/15

 

12.  Drawing No. A-700.00, Wall Types, Drawing No. A-701.00, Wall Types, Drawing No. A-702.00, Details (and other drawings); There is some F. T. Plywood and some FRT shown on these Wall Types (I believe intended to be the same).  This building is Type IA Construction.  Verify conformance with the allowable combustible Material in Type I and II Construction per IBC Sec. 603.1.  01/15/15

 

13.  Drawing No. A-700.00, Wall Types and Drawing No. A-701.00, Wall Types (and other drawings); As applicable, provide deflection tracking at the top of all new full height walls (at the underside of the roof structural members) per IBC Section 1604.  01/15/15

 

14.  Drawing No. A-740.00, BOH Floor Plan; The Accessible Lavatory Height in the Break Room shall be 34” maximum above the floor per "Accessible and Useable Buildings and Facilities"  (ICC/ANSI A117.1) 2003, section 606.3.  01/15/15

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter