Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C14-1704
Permit Type: Commercial Building Permit - None BldgCombo
Address: 1700 HILLCREST DR Anchorage
Location:
Work Description: 27,000 sq ft add'n & renovation in support of career technology classrooms @ West High School / tb
Status: Closed
Project Name: WEST HIGH SCHOOL
Review Type: Plumbing
Result: Approved
Result Date: 11/20/2014 11:23:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

Reviewed by: Bergstrom, Leigh W.                                             Permit #: C14-1704

Phone: 343-8326                                                                           Date: 11/20/2014

Fax: 249-7615

Email: BergstromLW@muni.org

Permit Manager: Tony Barganier

Phone: 343-8339

Email: BarganierTA@muni.org

Project: West High School

Review Number: 343763

 

1) STATUS:   8-18-14 Approved for underground plumbing only. Provide 100% drawings. Comments to be addressed.         11-03-14 COMMENTS TO BE ADDRESSED.         11-20-14 APPROVED.

 

2) The following comments based upon the 2009 Uniform Plumbing Code must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the Uniform Plumbing Code or any federal, state or local regulations.       RESOLVED 11-20-14.

 

3) WM200             A 6" incoming water service is shown on this page. On WM201 and WM702 is is shown as 8". Please clarify.       RESOLVED PER RESUBMITTAL RECEIVED 11-13-14.

 

4) WM201           Interior hose bib (HB-2) in other than a residential application is considered by the AWWA Cross Connection Control Manual to be a high hazard and would normally require an RP device; however the MOA has been allowing either PVB's or SVB's for this application.       RESOLVED PER RESUBMITTAL RECEIVED 11-13-14.

 

5) When the above comments have been addressed please update the plans at the MOA Plans Review Office with three sets of revised plumbing pages to include clouded changes, engineers stamp and signature.                       RE-SUBMITTALS ARE TO BE DIRECTED TO THE ATTENTION OF THE PERMIT MANAGER WITH A LETTER OF RESPONSE ADDRESSING EACH COMMENT.          RESOLVED 11-20-14.

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS