Permit Number: C14-1749
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description:

Comm T/I: non-structural partitions, soffits, fixtures, finishes, raised flooring system; includes elec, plbg, mech for Ste 147 / tb

SUITE NUMBER CHANGED TO 179 - TC

Status: Closed
Project Name: AT&T STORE
Review Type: Architectural
Result: Approved
Result Date: 9/2/2014 1:29:00 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

Reviewed by: Crafts, Donald E.                                                  Permit #: C14-1749

Phone: 343-8451                                                                        Date: 08/14/14, 09/02/14

Fax: 249-7652

Email: CraftsDE@muni.org

Permit Manager: Tony Barganier

Phone: 343-8339

Email: BarganierT@muni.org

Project: AT&T STORE - 800 E DIMOND BLVD

Review Number: 339307

 

1.  Status: Architectural Corrections required.  08/15/14   Status: Full Architectural Approval.  09/02/14

 

2.  The following comments based on the 2009 International Building Code (IBC) and 2009 International Existing Building Code (IEBC) must be resolved before a permit is issued.  The plans and specifications do not permit the violation of any section of the IBC or any federal, state, or local regulations.

 

3.  Drawing No. A-111, Floor Plan/Finish Plan and Drawing No. A-301, Wall Sections; There is FRT Plywood and Faux Wood Beams indicated on the Plans.  Verify conformance (for all combustible material) with the requirements in IBC Sec. 603 Combustible Material in Type I and II Construction, IBC Sec. 603.1, Allowable Materials.  08/15/14     DEFERRED SUBMITTAL.  09/02/14

 

4.  Drawing No. A-601, Door and Frame Types; The doors with mirrored glass panels require safety glazing per IBC section 2406.3.  Verify Safety Glass on both Door Types V1.  08/15/14    RESOLVED.  09/02/14

 

5.  Drawing No. A-808, Restroom Plan and Elevations; A minor CAD error exists in the Detail 2, Section B (North).  It appears that the vertical grab bar sliped toward the toilet room back wall from its 3'-4" dimention indicated.  08/15/14    RESOLVED.  09/02/14