Permit Number:
X14-1572
Permit Type:
Commercial Building Permit - ChangeOrdr BldgNew
Address:
2020 TIDEWATER RD Anchorage
Location:
Work Description:
Reducing building size to 4980 Sq Ft - BWP
Status:
Closed
Project Name:
Change Order of Bldg App C14-1410
Review Type:
Fire
Result:
Approved
Result Date:
6/30/2014 11:16:42 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
Approved 6/30/2014 per plans with following notation: Code study stated single exit building exit signs not required but two exits provided. Per IBC 1014.3 two exits required as common path exceeds 100 ft. exit signs also reuired and were redlined to the plans.