Permit Number: C13-2123
Permit Type: Commercial Building Permit - None BldgAlter
Address: 1700 HILLCREST DR Anchorage
Location:
Work Description:

CONTRUCTION OF AMMENITIES AS PART OF ONGOING STADIUM DEVELOPEMENT - TC

CONTRACTOR PAID FOR 3 MORE INSPECTIONS

Status: Closed
Project Name: WEST HIGH FOOTBALL FIELD
Review Type: Structural
Result: Approved
Result Date: 1/16/2014 2:56:10 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

PERMIT INFORMATION

Permit Number: C13-2123

Project Name: West high Football Field

Permit Manager: Tommy Cornell | ph: (907) 343-8181 | cornellta@muni.org

 

Plan Review: Mark Panilo | ph: (907) 343-8081  fax: (907) 249-7679 | panilomm@muni.org

 

Please submit all information through your Permit Manager.

 

REVIEW STATUS

01/07/2014 – Initial review (324892).  Comments issued.

 

GENERAL

This review is code compliance review based on the requirements of the International Building Code (IBC), 2009 Edition, and all adopted references thereto, as amended by the Municipality of Anchorage in Anchorage Municipal Code (AMC) Title 23.  This review does not permit the violation of the building codes, nor any federal, state, or municipal regulation.

 

The following comments must be addressed before a permit may be issued.  Additional comments may be issued following review of submitted information.

 

1. DESIGN INFORMATION

Please provide structural design information for the construction of the proposed structures and improvements.

Reference: IBC Section 1603.1

 

2. SPECIAL INSPECTION PERSONNEL

Please provide a letter from the Owner/Owner's Representative, or Special Inspection Agency stating that the Special Inspection Agency has been retained by the Owner to provide special inspection services for the project as required by IBC Chapter 17.

Reference: AMC 23.15.1704.1.4

 

3. STEEL FABRICATOR QUALIFICATIONS

Please provide a copy of the steel fabricator certification from AISC, IAS, or MOA for fabrication of structural steel without special inspection required by IBC Chapter 17.  In lieu of certification, please submit the name(s) and resume(s) of the individual(s) providing shop special inspection for review.

Note: This item may be deferred.

Reference:  IBC Section 1704.2.2; AMC 23.15.1704.1.4

 

4. BLEACHER DESIGN

Please provide design analysis and details for the bleacher construction, or provide a letter sealed by a Professional Engineer registered in the State of Alaska stating that the design and detailing of the bleachers conforms with the structural provisions of ICC 300.

Note: This item may be deferred.

Reference: IBC Section 1603.1, 1604.4; AMC 23.10.104.8.1