Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C13-1886
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description:

Comm T/I includes elec,plbg,mech / tb 

**Master fill/grade C13-1529; Core & Shell C13-1660**

Status: Closed
Project Name: CHILI'S
Review Type: Plumbing
Result: Approved
Result Date: 11/18/2013 1:58:00 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

Reviewed by: Bergstrom, Leigh W.                                             Permit #: C13-1886

Phone: 343-8326                                                                           Date: 11/05/2013

Fax: 249-7615

Email: BergstromLW@muni.org

Permit Manager: Tony Barganier

Phone: 343-8339

Email: BarganierTA@muni.org

Project: Chili's

Review Number: 323478

 

1) STATUS:   11-5-13 Comments to be addressed.    

 

2) The following comments based upon the 2009 Uniform Plumbing Code must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the Uniform Plumbing Code or any federal, state or local regulations.

 

3) P101           All of the floor drains require trap seal protection. (UPC 1007.0)

 

4) P101           The waste water from the soak sink and the pre-rinse sink in the dish washing area should be processed through food strainers and into a grease interceptor (UPC 1014.1)

 

5) P101           If any food (canned, bottled or otherwise) is to be stored in Utility #120, the floor drain shall have indirect piping. (UPC 411.3) Please clarify.

 

6) When the above comments have been addressed please update the plans at the MOA Plans Review Office with three sets of revised plumbing pages to include clouded changes, engineers stamp and signature.                       RE-SUBMITTALS ARE TO BE DIRECTED TO THE ATTENTION OF THE PERMIT MANAGER WITH A LETTER OF RESPONSE ADDRESSING EACH COMMENT.

 

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter