Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C13-2016
Permit Type: Commercial Building Permit - None BldgCombo
Address: W 716 4TH AVE Anchorage
Location:
Work Description:

17,942 SQ FT ADD'N & $7,901,250 COMM T/I / TB

9/23/2014 PAID $4800 IN PAST DUE FEES, AND $ 5200 IN FUTURE FEES-GJS

 

12/24/2014 paid $8850 for 59 inspections plus picked up change orders.BWP

Status: Closed
Project Name: LEGISLATIVE INFORMATION OFFICE
Review Type: Architectural
Result: Correction
Result Date: 12/5/2013 7:18:19 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

Reviewed by: Crafts, Donald E.                                                  Permit #: C13-2016

Phone: 343-8451                                                                        Date: 12/02/13

Fax: 249-7652

Email: CraftsDE@muni.org

Permit Manager: Tony Barganier

Phone: 343-8339

Email: BarganierT@muni.org

Project: LEGISLATIVE INFORMATION OFFICE - 716 W 4TH AVE

Review Number: 323306

 

1.  Status: Architectural Corrections required.  12/02/13  Please resolve Code Analysis comments.  More comments may follow depending on comment resolution.  12/02/13

 

2.  The following comments based on the 2009 International Building Code (IBC) and 2009 International Existing Building Code (IEBC) must be resolved before a permit is issued.  The plans and specifications do not permit the violation of any section of the IBC or any federal, state, or local regulations.

 

3.  Drawing G1.00, 2009 IBC Code Analysis; The Chapter 5 analysis indicates both S-1 and S-2 occupancy types.  Is it intended to indicates both S-1 and S-2 or is it supposed to only indicate an S-2 occupancy type?  Note S-1 is indicated in Chapter 9 as well.  12/02/13

 

4.  Drawing G1.00, 2009 IBC Code Analysis; The Chapter 5 analysis indicates no separation is required per Table 508.4.  This is not true.  A 1 hour separation is required between an A occupancy and a B occupancy per Table 508.4.  A 1 hour separation is also required between an A occupancy and an S-1 occupancy per Table 508.4 (I believe that you can make the S-1 occupancy go away).  12/02/13

 

5.  Drawing G1.00, 2009 IBC Code Analysis; The Chapter 6 analysis indicates that non-bearing exterior walls are 1 hour at greater than or equal to 30 feet (Table 602).  Is this intended to indicate that non-bearing exterior walls are 1 hour at less than 30 feet (Table 602) and 0 hour at greater than or equal to 30 feet (Table 602)?  12/02/13

 

6.  Drawing G1.00, 2009 IBC Code Analysis; The Chapter 9 analysis indicates that manual fire alarms are provided and identifies a reference to 907.2.9.1.  Note that 907.2.9.1 applies only to R-2 occupancies.  12/02/13

 

7.  Drawing G1.00, 2009 IBC Code Analysis; The Chapter 11 analysis indicates that the building cannot fully comply with Chapter 11 requirements.  For existing building features, you can apply the technically infeasible claus of IEBC Section 605, as applicable.  Note that the addition must fully comply with Chapter 11 requirements.  12/02/13

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS