Review Type: Storm Water
Result: Approved
Result Date: 11/2/2012 2:40:00 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

1. Complete an AG 21 Checklist #2.  Provide the required documentation for a project with this area of disturbance; SWPPP type 2, Operations and Maintenance Manual, etc... RESOLVED SME 6-20-12.

2. SWPPP and NOI provided. AKR10EC54. sme 6-18-12.

3. OK for grading and excavation not to exceed 5 feet in depth.  No excavation dewatering or ultility work allowed. sme 6-18-12. RESOLVED SME 6-20-12.

4.  Complete AG 21 checklists 2 and 3. RESOLVED SME 6-20-12.

5. Provide ESC plan. RESOLVED SME 6-20-12.

6. Provide a dewatering plan.  Ground water will be pumped into a tanker and hauled to a legal disposal location (AWWU).  RESOLVED SME 6-20-12.

7. Provide an Operations and Maintenance Manual. RESOLVED. SME 11-2-12.

8. Show permanent storm water treatment. RESOLVED. SME 11-2-12.

9. Complete the corrections for items 4 and 5 by June 20, 2011 or a stop work order may be posted. sme 6-18-12. RESOLVED SME 6-20-12.

10. OK for Shell Permit. sme 6-20-12.

11. OK for full permit. sme 11-2-12.

 

 