Permit Number: C11-1309
Permit Type: Commercial Building Permit - None BldgAlter
Address: 3101 PENLAND PKWY Anchorage
Location: INCLUDES 14, 18, 24, 26, 27
Work Description: TENANT IMPROVEMENT FOR FITNESS CLUB, INCLUDES LIGHTING, PLMB AND MECH (JINNY ROSE DAY)
Status: Closed
Project Name: PLANET FITNESS
Review Type: Architectural
Result: Approved
Result Date: 6/22/2011 3:38:00 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

1) STATUS:   6-9-11 Comments to be addressed.               6-22-11 APPROVED.

 

2) The following comments based upon the 2006 International Building Code (IBC) must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the IBC or any federal, state or local regulations.               RESOLVED 6-22-11.

 

3) T1.0               The list of applicable codes should also include the 2003 ICC/ANSI A117.1 "Accessible and Useable Buildings and Facilities".       RESOLVED PER RESUBMITTAL RECEIVED 6-15-11.

 

4) A1.0               Wall Type 3 requires a slip track at the top of wall to accomodate varying winter snow loads on the roof. Please clarify.           RESOLVED PER RESUBMITTAL RECEIVED 6-15-11.

 

5) 2/A1.1             The horizontal water closet grab bar also has a maximum height of 36" to the top of the gripping surface. (ICC/ANSI A117.1-609.4) RESOLVED PER RESUBMITTAL RECEIVED 6-15-11.

 

6) 2/A1.1             A vertical side wall grab bar is also required. (ICC/ANSI A117.1-604.5.1)           RESOLVED PER RESUBMITTAL RECEIVED 6-15-11. 

 

7) When the above comments have been addressed please update the plans at the MOA Plans Review Office with three sets of revised architectural pages to include clouded changes, engineers stamp and signature.              RESOLVED 6-22-11.

 