Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 10 5130
Permit Type: Commercial Building Permit - None BldgNew
Address: 4951 BUSINESS PARK BLVD Anchorage
Location: 4951 BUSINESS PARK BLVD 00922134000
Work Description: Work Descr: 41,004 sq ft (B), 1090 sq ft (S), 1010 sq ft (A3), Remarks: JRD
Status: Closed
Project Name: ANCHORAGE NEIGHBORHOOD CLINIC
Review Type: Traffic Engineering
Result: Correction
Result Date: 4/1/2011 4:18:00 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

 

1.) Traffic review is incomplete pending a complete Zoning review and checklist for off street parking, loading berths and snow storage. 

 

2.) General Note number 17 on SHT. C-101 has been noted.  Traffic is aware that a contractor may not presently be selected for this work.  Please note that the earthwork contractor shall need to provide the proposed haul route infomation prior to approval of the building permit by the Traffic division. The proposed haul route will be from Quality Asphalt Products pit at C Street to West International Road to Business Park Boulevard to the site.  The reverse order shall be used for the return route. 

 

3.) SHT. C-103 illustrates Temporary Snow storage areas at the locations of approximately fifty (50) parking stalls.  Temporary Snow storage shall not be placed at areas designated for required off-street parking.

 

4.) On SHT. C-105, please provide additional spot grade elevations to demonstrate that all ADA accessible parking stalls and access aisles shall be level with surface slopes not to exceed 2% in all directions.  

 

5.) Show all traffic ingress and egress flow arrows for parking area circulation.  

 

6.) Show curb return radii dimensions for Business Park Blvd. driveways. 

 

7.) On SHT. 512, (Detail 01/C-512) for the far right 9'-6" Van Accessible space shall have an eight (8) foot aisle, please adjust.

 

8.) Sheet E 1.0: Provide a stamped Certified Site Lighting and Glare Analysis statement for the parking area per AMC 21.45.080.X.e.

 

9.) This review shall be considered incomplete pending receipt and approval of the requested information and/or additional comments.

 

10.) Approved for footing and foundation work only.  4/1/11 ~DF~

 