Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 10 4261
Permit Type: Commercial Building Permit - None BldgAlter
Address: 5600 DEBARR RD Anchorage
Location:
Work Description: Work Descr: interior t/i of office space in existing commercial space, Remarks: mgm **OK for Andrew to p/u permit per Mike Fall w/ Unit Company**tb
Status: Closed
Project Name: CARRS/SAFEWAY REGIONAL ADMIN O
Review Type: Fire
Result: Approved
Result Date: 7/12/2010 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): FIRE REVIEW STATUS: 6/24/10 RESUBMITTAL. APPROVED 7/12/10 6/4/10. RESUBMITTAL OF 5/20/10. DISAPPROVED. CommentS#13 & #16 unresolved; additional comments #19,#20. 5/4/10 INITIAL FIRE REVIEW. DISAPPROVED. C(2): The following comments are based on the 2006 International Fire Code (IFC), the 2006 International Building Code (IBC) and state and local amendments and must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the IFC, IBC or any federal, state or local regulations. Advisory comment only. No response required. C(3): CODE STUDY: Provide a complete code study for the building to include, occupant load determination (based on net or gross), and exiting formula used and determination of number of exits required and number provided. Please address. IBC 1004, 1005. RESOLVED.Added. 6/4/10 Venta C(4): OCCUPANT LOAD: shall be not less than the number determined by dividing the floor area by the Table 10-A O/L factor for the specific use - B Occupancy. Please address and show on plans. IBC 1004.3.. RESOLVED. Added. 6/4/10 Venta C(5): ASSEMBLY OCCUPANCY ROOMS: Every room or space that is an assembly occupancy shall have the occupant load posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Video Conf #113; Training #111; Sm Conf rms #117, #118, #119. IBC 1004.3 RESOLVED. Signage added. 6/4/10 Venta C(6): ADDRESS: Provide a street address/Suite Number for the building. The address shall be plainly visible/legible from thestreet or road fronting the building. (DeBarr address) IFC 505.1. RESOLVED Added. 6/4/10 Venta C(7): KNOX KEY BOX: Knox box required adjacent to the front main entrance no higher than 6 ft. above grade - prior to the Fire Final Inspection. Knox box info may be obtained at Fire Prevention 4700 S Bragaw, 267-4900. IFC 506. RESOLVED. Added. 6/4/10 C(8): FIRE PROTECTION SYSTEMS - EMERGENCY GENERATOR - PERMIT: Emergency Generator shown in Alternate D requires a separate permit. Submit plans and apply for separate review and permit. Contact Mark Warren, Fire Systems Plan Review 267 4992 for details. Deferred submittal acceptable is Alternate D is used. RESOLVED. Deferred submittal 6/4/10 Venta C(9): EXIT SIGNS: Provide illuminated exit signs with a backup source of power to meet code. Please show on plans. IBC 1011.2. RESOLVED. Added one and shown on plans. 6/4/10 Venta C(10): ROLL DOWN FIRE DOOR: Provide current test report for existing fire door showing operates as intended. What is rating of fire door and wall it protects? Please address. IBC 715.4. RESOLVED. Test report will be submitted. 6/4/10 Venta C(11): FIRE PROTECTION SYSTEMS - SPRINKLER SYSTEM -Permit: Sprinkler system may require a separate permit depending on reconfigurataion. Submit plans and apply for separate review and permit. Contact Mark Warren Fire Systems Plan Review 267 4992 for details. Deferred submittal acceptable. RESOLVED. Deferred submittal. 6/4/10 Venta C(12): FIRE PROTECTION SYSTEMS - FIRE ALARM -Permit: Fire Alarm system may require a separate permit depending on reconfiguration. Submit plans and apply for separate review and permit. Contact Mark Warren Fire Systems Plan Review 267 4992 for details. Deferred submittal acceptable. RESOLVED. Deferred submittal. 6/4/10 Venta C(13): FIRE PROTECTION SYSTEMS-REPORTS: Provide a current Annual Service & Test Report for each fire system in the building - fire alarm and sprinkler system. All deficiencies must be corrected prior to calling for a fire final for CO. 6/4/10 Recd Sprinkler system Annual Service & Test Report showing numerous deficiencies, which must be corrected by property manager prior to CO. Need Fire Alarm ASTR report. RESOLVED. vENTA 7/12/10 C(14): EXIT ILLUMINATION: Provide exit illumination with emergency backup power to provide a light intensity of not less than 1 footcandle at floor level throughout all areas. Show on plans! Uniform Fire Code 1211.1. RESOLVED. Em lighting procided to meet code. Powered by Emergency generator. 6/4/10 Venta C(15): EMERGENCY LIGHTING - EXTERIOR: Emergency Lighting required at exit discharge (outside) IBC 1006.3.5. RESOLVED. Added exterior EM lights. 6/4/10 Venta C(16): EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. Nokeyed locks except front main entrance (if one door or a single pair). PLEASE NOTE; NO THUMBTURNS ALLOWED ON EXIT DOORS. All 4 exit doors on hardware schedule show thumb turns A-601. Please address conflict. 6/4/10 Venta. RESOLVED. AGREED. Venta 7/12/10 C(17): VERTICAL SHAFT FIREBLOCKING: Sht M111. Vertical Shaft shall meet requirements of IBC 716.5.3. Shart needs fire blocking every 10 ft. IBC 716.5.3 and 717. Please address and show on plans. RESOLVED. Note added to plans. 6/4/10 Venta C(18): Please provide written response to the comments above and attach one copy of additional or revised calculations and two copies of additional or revised drawings. Please note that additional comments may be generated from the response to these comments. Advisory comment only. No response required. C(19): FIRE EXTINGUISHERS: Fire extinguishers required to meet IFC 906 requirements throughout. Minimum size 2A10BC mounted and visible, available within 75 ft travel distance from any location in suite. Please show on plans. Inspector to field verify. RESOLVED. Venta 7/12/10 C(20): INTERIOR FINISHES CHAPTER 26: All interior finish materials required to meet IBC Chapter 26 requirements for flame spread and smoke development. Please verify. IBC 26 RESOLVED. AGREED AND NOTED ON PLANS. Venta 7/12/10
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS