Permit Number:
09 5120
Permit Type:
Commercial Building Permit - None BldgNew
Address:
6250 SOUTH AIRPARK PL Anchorage
Location:
6250 SOUTH AIRPARK PLACE
Work Description:
Work Descr: 19873 sqft-B, 21,137 sqft S1, Remarks: JRD
Status:
Closed
Project Name:
NORTHERN HOLDINGS
Review Type:
Architectural
Result:
Approved
Result Date:
6/11/2010 12:00:00 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. Status: Architectural Corrections required. 1/13/10 Status: Full Architectural Approval. 5/7/10 The following comments based on the 2006 International Building Code (IBC) must be resolved before a permit is issued. The plans and specifications do not permit the violation of any section of the IBC or any federal, state, or local regulations. Sheet No. A0.1, Code Analysis, A manual fire alarm system is required in accordance with IBC Section 907.2.2 and Local Amendment 23.15.907.2.2 (which deletes the exception) for a B occupancy with more than 100 occupants above the lowest level of exit discharge. Add the following to the Code Analysis: A manual fire alarm system is required in accordance with IBC Section 907.2.2. 1/12/10 RESOLVED. The code study was modified to include: A manual fire alarm system is required in accordance with IBC Section 907.2.2. 5/7/10 Sheet No. A0.1, Code Analysis, IBC Ch. 29, A tabulation of the required number of fixtures based on the occupant load is not calculated and the Code Analysis does not include a code evaluation indicating separate sex accessible toilet rooms/facilities required per IEBC Sec. 605, IBC Sec. 1109.2 and IBC Sec. 2902.2. Please update the Code Analysis to include the required number of fixtures and accessible toilet rooms/facilities required. Note: It appears that the required total number of fixtures and the required number of separate sex accessiblefixtures has been satisfied. 1/12/10 RESOLVED. The code study was modified to include a tabulation of the required number of fixtures based on the occupant load. 5/7/10 Sheet No. A0.2, The wall types 1, 5A, and 5B for the exterior walls includes a 3 inch Metecno-API 200 series panel which appears to contain foam plastic. A thermal barrier is required per IBC Section 2603.5 for the exterior wall (foam plastic) or show compliance to the requirements in IBC Section 2603.5.1 thru 2603.5.7 or show compliance to the requirements in IBC Section 2603.9. Please provide exterior wall cut sheets and details to include the thermal barrier or clarify code compliance. 1/12/10 RESOLVED. Exterior wall cut sheets and details were provided that include verification of code compliance. 5/7/10 Sheet No. A2.1 and A2.3, Floor Plans; The plan does not indicate an exit sign in the direction of exit travel in the corridor toward the Commons 120 near Men 122 and Elevator 123. Provide an exit sign in the direction of exit travel near Men 122 and Elevator 123 per IBC Section 1011.1. 1/12/10 RESOLVED. The plan now indicates an exit sign in the direction of exit travel in the corridor toward the Commons 120 near Men 122 and Elevator 123. 5/7/10 Sheet No. A2.2 and A2.4, Floor Plans; The plan does not indicate an exit sign in the direction of exit travel for the corridor toward the Reception 222 outside Door 225. Provide an exit sign in the direction of exit travel outside Door 225 per IBC Section 1011.1. 1/12/10 RESOLVED. The plan now indicates an exit sign in the direction of exit travel for the corridor toward the Reception 222 outside Door 225. 5/7/10 Sheet No. A2.3, Toilet Accessory Schedule, After Drawing Tab E, add a new line item for an18 inch stainless steel grab bar. 1/12/10 RESOLVED. The plan now indicates an 18 inch stainless steel grab bar. 5/7/10 Sheet No. A2.3, A2.4, A2.5, A3.5, A3.6, and A3.8, The bathroom accessible W.C.s require GrabBars per ICC/ANSI A117.1 sections 604.5 and 609. For all bathroom accessible W.C.s, please provide the 18 inch vertical grab bar located 39 to 41 inches from the back wall and 39 to 41 inches from the floor as shown on ICC/ANSI A117.1 Fig. 604.5.1. 1/12/10 RESOLVED. The plans now indicate 18 inch stainless steel grab bars. 5/7/10 Sheet No. A2.4, The wall type for the elevator shaft is not identified. Please indicate onthe plan. 1/12/10 RESOLVED. The wall type for the elevator shaft is now identified. 5/7/10 Sheet No. A3.3 and 3.4, The roofing assemblies include a 5 inch Metecno-API 1000 series panel which appears to contain foam plastic. A thermal barrier is required per IBC Section 2603.4.1.5 for the roofing (foam plastic) or show compliance to the requirements in IBC Section 2603.4.1.5 or show compliance to the requirements in IBC Section 2603.9. Please provide roofing cut sheets and details to include the thermal barrier or clarify code compliance. 1/12/10 RESOLVED. 5 inch Metecno-API 1000 series panel cut sheets and details were provided that include verification of code compliance. 5/7/10 Sheet No. A4.1 Detail 1 (at column lines 1 and 2), No. A5.3 Detail 4, and A5.3 Detail 7 Theroof parapit contains 1/2 inch plywood identified as exterior exposure. The allowable combustible materials are identified in IBC Section 603.1 for Type IIB Construction. Is the 1/2 inch plywood fire-retardant-treated wood per the requirements of IBC Section 603.1 for Type IIB Construction? 1/12/10 RESOLVED. The plans no longer indicates 1/2 inch plywood as exterior exposure. 5/7/10 Drawing Nos. Various, All Wall, Ceiling and Roof Assembly Sections, The insulation R values are mostly identified on the Drawing Plan Set. The insulation R values for Doors and Windows are not identified on the Drawing Plan Set as submitted. Please provide assurance that the Building Envelope meets or exceeds the Energy Efficiency requirementsof IBC Section 1301.1 and The International Energy Conservation Code (IECC) Chapter 5 and Local Amendments to IECC Chapter 5 requirements. Show compliance with the requirements of Climate Zone 7 in IECC Table 502.2(1) and 502.2(3) as well as the Local Amendment to IECC Table 502.2(1) on unheated slabs. 11/13/10 RESOLVED. The plans indicate that the Building Envelope meets or exceeds the Energy Efficiency requirements of IBC Section 1301.1 and The International Energy Conservation Code (IECC) Chapter 5 and Local Amendments to IECC Chapter 5 requirements. 5/7/10
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501