Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
09 5071
Permit Type:
Commercial Building Permit - None BldgNew
Address:
2810 O'MALLEY RD Anchorage
Location:
Work Description:
Work Descr: 4284 SQ FT, Remarks: JRD
Status:
Closed
Project Name:
GREEK ORTHODOX CHURCH
Review Type:
Fire
Result:
Approved
Result Date:
3/19/2010 12:00:00 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. FIRE REVIEW STATUS: DISAPPROVED 12/29/2009 Carpenter DISAPPROVED 2/5/2010 Carpenter DISAPPROVED 3/3/2010 Carpenter APPROVED 3/19/2010 Carpenter WATERFLOW: Provide information on flow available. Show hydrant locations & distances from property and building. AWWUcomputer projections may be accepted for permitting. Call AWWU 564-2729. 2000 gpm required. NO WATER AVAILABLE ADDRESS: Provide a street address for the building. The address shall be plainly visible/legible from the street or road fronting the building. IFC 505.1 Each building at this site shall be individually identified for emergency responders to differentiate between buildings. The address (s) shall also be out at O'malley Road location also. RESOLVED 3/3/10 FIRE ACCESS: Provide a 20' wide lane to within 150' of all portions of the building. Use a minimum clear height of 13'6" and a 40' inside diameter turn radius. Show intended access on the plans. RESOLVED Provide approved "NO PARKING FIRE LANE" signs. Show all locations. NOT RESOLVED 3/3/10 FIRE Lane signs shall be posted maximum 150 feet apart along entire length from both entries at O'Malley road around the loop. RESOLVED WILL BE INSTALLED. Floor Construction required to be two hour construction and is shown to be on Sheet AO.2. Verify/ provide that all elements construction supporting this horizontal assembly are also rated for two hours. Include individual protection for columns and beams. RESOLVED Fire Resistive Rating: Shaft enclosures shall have a rating of not less than the floor assembly penetrated (two hours). IBC 707.3 Verify/provide 1 hour separation for boiler room with 45 MIN rated door and Fire smoke dampers for duct penetrations.IBC Table 508.2. RESOLVED OCCUPANT LOAD CALCULATIONS: Maximum chair seating is listed as 217 seats for Nave. Provide occupant load factor from IBC Table 1004.1.1 that is used and area in square footage used for the Nave. What is the exact area of the Nave?? The Banquet Hall is shown to use an occupant load factor of 15 to compute the occupant load. Would this space not be utilized for dancing and other functions that utilized only chairs that would elevate the occupant load?? Also, the Narthex is shown to have an Occupant Load of 30 using an Airport function?? The OCCUPANT LOAD is critical in determining whether a Fire Sprinkler is required or not. The threshold is 300 or more persons to require one. Any deviation from prescriptive method shall be with the approval with the Fire Marshal and Building Official. RESOLVED ACCEPTED by Martin Schwan AFM 3/3/2010 FIRE PROTECTION SYSTEMS - Permits: Submit plans and apply for separate review and permits for FIRE ALARM SYSTEM. Contrary to Code Study note, IBC 907.2.1 requires a Fire Alarm in A "occupancies" having an occupant load of 300 or more. Acting Fire Marshal Schwan requires Manual Fire Alarm system per code reading. 3/3/10 NOT RESOLVED RESOLVED Fire Alarm system will be provided. 3/18/20010 per Pat Krochina Letter of March 11,2010. IBC 901.6.2: Requires fire alarm to be monitored at a 24 hour approved location. NOT RESOLVED see #10 RESOLVED IT WILL BE PER KROKINA Stair Enclosure: Wall separating basement from stair required to maintain 2 hour fire area separation so as not to exceed the limits requiring a Sprinkler System. This would serve to envelope the required 2 hour rated separation. Door 105 required to be 90 minute fire door. IBC 901.7 NOT RESOLVED: This may now be a horizontal exit and the 2 hour wall is required to be full height for accessibility. RESOLVED - WILL GO TO ROOF DECK. Storage 102 requires 1 hour fire-resistive separation. Door 102 required to be 3/4 hour fire door. Doors 105 and 212B require panic hardware. RESOLVED SPRINKLER SYSTEM: A sprinkler system is required in an A-3 if the fire area is located on a floor other than the level of exit discharge. The basement has only one exit on a floor at the level of exit discharge and if the occupant load in the fire area has an occuopant load of 300 or more people. Please address. RESOLVED EXIT ARRANGEMENT: 2 exits shall be placed a distance apart = than 1/2 the max. overall diagonal of the area served. IBC1015.2.1 Basement exiting separation is deficient. NOT RESOLVED 3/3/2010 RESOLVED 3/18/10 IBC 804.4.1 Interior floor finish requirements for minimum critical radiant flux shall be Class I in exit enclosures.Please address the carpet. RESOLVED 3/3/2010 Maximum Occupant Load signs: Provide for main assembly rooms. NOT RESOLVED3/3/2010: Signs shall include in large redletters "By Order of Fire Marshal" RESOLVED SEE COMMENT #9 ABOVE: Provide exiting calculations for number and width required. RESOLVED EXIT SIGNS: (a) Add basement at approximate Grid lines 4 and E.5 to direct to exit at Door 105. (b) Add Narthex to direct to exit door 212B and at Door 212B. NOT RESOLVED- NOT addressed. 3/3/2010 Resolved /verify on inspection IBC 1006.4 Emergncy Lighting performance of system shall meet requirements of this section. Verify/provide. RESOLVEDwill verify on inspection. FIRE EXTINGUISHERS: Provide fire extinguishers. 2A10BC minimum required within 75 ft of foot travel throughout. RESOLVED 3/3/2010 Wall Types 7 & 8 on Sheet A5.6 and Wall type 3A on Sheet A5.5 are have sheetrock on only one side. They are required 1 hour interior walls. NOT RESOLVED 3/3/2010 Verify/ resolved IBC 717Concealed Spaces: Indicate intended areas of fireblocking and or draftstopping. Raised platform in sanctuary is an example. RESOLVED 3/3/2010 WILL DO Fiberglas Domes: Provide complete details of construction to include type of insulation, flame-spread and smoke development index. Shall meet requirements of IBC Chapter 8 for interior finish. Is there foam plastic insulation? Thermal barrier etc. NOT RESOLVED 3/3/2010 More details required. DEFERRED SUBMITTAL IBC 1025.12 Seat Stability: Verify/provide compliance with this section. NOT RESOLVED 3/3/2010- MORE THAN 200 CHAIRS ARE SHOWN. RESOLVED 3/19 /2010 Per Krochina the chairs will meet this code section when they exceed 200 chairs EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. NOTED 3/3/2010 SIGNS: Provide signs: Electrical Rooms, Boiler Rooms, Fire/Smoke damper locations, Electric Service Main Disconnect, Machine Maximum Occupant Load Sign for assembly rooms. etc. RESOLVED AUTOMATIC SHUTOFFS (activated by smoke detection): Required in each system providing over 2000 cfm heating or cooling air. Verify/ Provide RESOLVED IBC 502 BASEMENT DEFINITION: Is the basement a story above grade plane per this definition??? NOTED as basement. SUBMITTAL LETTER OF JAN 14, 2010 from Krockina. 2/5/2010: Letter did not address any of the above comments. Theimportant occupant load calculations are still unanswered.
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501