Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 08 5199
Permit Type: Commercial Building Permit - None BldgAlter
Address: 1200 L ST Anchorage
Location:
Work Description:

Work Descr: Wireless antenna installed to rooftop w/ MW & Wimax antenna, Remarks: tb

PERMIT EXPIRED, NO ISSUANCE, PLANS AND FOLDER DESTROYED-GJS 9/4/2015

Status: Closed
Project Name: INLET TOWER
Review Type: Structural
Result: Approved
Result Date: 2/25/2009 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): PERMIT STATUS (no response required) 11/18/08: Review started, not complete due to comment #3. Comments issued. REW 11/08/08. Comments issued, no change in permit status. REW 1/29/2009 Comments issued. REW 2/20/09 Approved 2/25/09 REW. C(2): Advisory Comment (no response required): This review is based on the requirements of the Anchorage Administrative Code (AAC), 2006 International Building Code (IBC) and all adopted references thereto as amended by MOA. The following comments must be addressed before a permit can be issued. The approval of plans and specifications does not permit the violation of the codes, or any federal, state or local regulations. REW 11/18/08. C(3): CALCULATIONS: Provide calculations for all proposed additions and modifications to existiing structure. The analysis should include wind, seismic, gravity and lateral loading for all new and proposed elements. Provide details that encompass all attachements and modifications to existing structure. Reference IBC 1603, 1604 and AMC 23.10.302.2. REW 11/18/08. The recent submittal does not include the calculations requested. A letter stating that a structural analysis was performed was received, however the letter states that structural data specific to the areas of the installation were not provided. Please aquire the information to accurately review and engineer this projeect and resubmit with the requested calculations. REW 1/29/2009 C(4): PLANS: (New Comment) Permit is approved after reviewing recent calcluation. Please provide plans that indicate the required four (4) 5/8" diameter anchor bolts to secure the equipment cabinets to the structure. Additionally, the plans must show the required ballast weight and location. This will enable our inspectors to verify that the work has been done in accordance with the approved plan. This could be as simple as a couple of details on 8-1/2" x 11" paper that can be attached to the existing plans. It is required to be stamped by an engineer registered in the state of Alaska.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS