Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 08 5043
Permit Type: Commercial Building Permit - None BldgAdd
Address: 2801 DEBARR RD Anchorage
Location:
Work Description: Work Descr: 2,689 sq ft add'n & T/I, Remarks: tb
Status: Issued
Project Name: ALASKA REGIONAL LAB & PHARMACY
Review Type: Structural
Result: Approved
Result Date: 3/16/2009 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): PERMIT STATUS 10/21/2008 - Initial review. Comments issued. 11/7/2008 - Reviewed responses. Special inspection information required. 1/27/2009 - Approved C(2): GENERAL This review is based on the requirements of the International Building Code (IBC), and the International Existing Building Code (IEBC), 2006 Editions, and all adopted references thereto, as amended by the Municipality of Anchorage in Anchorage Municipal Code (AMC) Title 23. The following comments must be addressed before a permit can be issued. Approval of the submitted plans and specifications does not permit the violation of the Building Code, nor any Federal, State, or Municipal regulations. C(3): DEFERRED SUBMITTALS The following items have been noted on Sheet S1.1 to be submitted under deferred status: 1) Outside air hood (OH-1) connection 2) Anchorage of mechanical equipment to housekeeping pad All deferred submittals must be sealed by a Professional Engineer licensed in the State of Alaska. Submittals must be reviewed for general conformance by the Registered Design Professional prior to submitting to Building Safety for review. Deferred submittals must be reviewed and approved by Building Safety prior to installation/construction. Reference: AMC 23.10.302.4.2 11/7/08 - Resolved. Deferred submittals acknowledged. MMP C(4): SPECIAL INSPECTION PERSONNEL Please provide a letter from the Owner/Owner's Representative, or Special Inspection Agency stating that the Special Inspection Agency has been retained by the Owner to provide special inspection services for the project as required by IBC Chapter 17. Reference: AMC 23.15.1704.1.4 11/7/08 - Not resolved. No information provided this review. Please provide as indicated above. MMP 1/27/09 - Resolved. Special inspection letter provided by ARH. MMP C(5): DETAIL NOTE CLARIFICATION Many of the details shown on Sheet S3.1 and S3.2 appear to have drafting errors, such that the fractional sizes of structural elements cannot be determined from the plans. Please provide revised details. Reference: AMC 23.10.302.3 11/7/08 - Resolved. Plans updated clarifying notes. MMP C(6): SHALLOW FOUNDATION AT EXISTING BUILDING Refer to Sheet S2.1, and Detail 4/S3.2. It is unclear how the shallow foundation transitions to the existing foundation at Grids K/13, and L.2/20.8. This includes both the grade beam and insulation. Please advise. Reference: AMC 23.10.302.3 11/7/08 - Resolved. Foundations for new construction placed over existinggrade beams and competent NFS material. No changes required. MMP
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS